The 12T/H Industrial Reverse Osmosis Water Treatment System is a fully automatic industrial water purification equipment with a rated output of 12m³/h (12000L/H). Equipped with customized pretreatment and RO membrane desalination technology, it effectively removes water hardness, dissolved salts, suspended solids and organic impurities. Designed for stable 24/7 operation, this skid-mounted RO plant is widely used for factory process water, boiler feed water, industrial park centralized water supply and commercial water purification projects.
The 12T/H Industrial Reverse Osmosis Water Treatment System is a fully automatic industrial water purification equipment with a rated output of 12m³/h (12000L/H). Equipped with customized pretreatment and RO membrane desalination technology, it effectively removes water hardness, dissolved salts, suspended solids and organic impurities. Designed for stable 24/7 operation, this skid-mounted RO plant is widely used for factory process water, boiler feed water, industrial park centralized water supply and commercial water purification projects.
|
Item
|
Specification
|
|
Product Name
|
12T/H Industrial Reverse Osmosis Water Treatment System
|
|
Rated Water Capacity
|
12m³/h (12000L/H)
|
|
Stable Operating Range
|
10–13m³/h
|
|
Core Technology
|
Multi-stage Pretreatment + Single-pass RO Desalination
|
|
Operation Mode
|
Fully Automatic Continuous Operation
|
|
Installation Type
|
Skid-mounted / Containerized customizable
|
|
Water Quality Parameter
|
Standard Performance
|
|
RO Salt Rejection Rate
|
≥97%
|
|
Finished Water Turbidity
|
≤1 NTU
|
|
Hardness & Scaling Substances
|
Fully removed
|
|
Suspended Solids & Impurities
|
100% intercepted
|
|
Finished Water Status
|
Clear, low conductivity, no scaling risk
|

|
Optional Upgrade
|
Application Function
|
|
Iron & Manganese Removal System
|
Solve groundwater metal ion exceeding problem
|
|
Ultrafiltration Pretreatment
|
Adapt to high-turbidity surface water
|
|
Water Softener
|
Treat high-hardness raw water and prevent scaling
|
|
Double-pass RO / EDI System
|
Produce high-purity industrial water
|
|
UV / Ozone Disinfection
|
Sterilization for domestic and drinking water
|
|
CIP Cleaning System
|
Regular membrane cleaning to extend service life
|
|
PLC Remote Monitoring
|
Real-time water quality data and fault alarm
|
|
Containerized Structure
|
Outdoor mobile installation for remote projects
|
|
Parameter
|
Specification
|
|
Rated Water Output
|
12m³/h
|
|
RO Type
|
Single-pass RO (Double-pass optional)
|
|
Salt Rejection Rate
|
≥97%
|
|
Water Recovery Rate
|
70%–75% (customizable)
|
|
Working Temperature
|
5℃–45℃
|
|
Control Mode
|
Automatic PLC intelligent control
|
|
Pipeline Material
|
UPVC / SS304 / SS316 optional
|
|
Power Supply
|
380V 50/60Hz customizable
|
|
Installation Method
|
Skid-mounted / Containerized
|
Q: Can the equipment run 24 hours continuously?
A: Yes. The industrial-grade fully automatic design supports 24/7 uninterrupted operation, suitable for long-term industrial production scenarios.
Q: Can RO treated water be used for boiler feed water?
A: Yes. It is the ideal pretreatment for boiler water. We can configure double-pass RO or EDI according to different boiler pressure standards.
Q: Is the equipment customizable?
A: Fully customizable. We adjust pretreatment process, material grade, automation level and post-treatment units according to actual water quality and project demands.
Q: Does the system remove iron and manganese from water?
A: RO can reduce part of metal ions. For water with high iron and manganese content, professional removal pretreatment is required.
Q: Can the finished water be used for drinking?
A: It can reach drinking standard with additional UV/ozone disinfection. Final water quality needs to pass local official laboratory testing.
|
Item
|
Specification
|
|
Product Name
|
12T/H Industrial Reverse Osmosis Water Treatment System
|
|
Rated Water Capacity
|
12m³/h (12000L/H)
|
|
Stable Operating Range
|
10–13m³/h
|
|
Core Technology
|
Multi-stage Pretreatment + Single-pass RO Desalination
|
|
Operation Mode
|
Fully Automatic Continuous Operation
|
|
Installation Type
|
Skid-mounted / Containerized customizable
|
|
Water Quality Parameter
|
Standard Performance
|
|
RO Salt Rejection Rate
|
≥97%
|
|
Finished Water Turbidity
|
≤1 NTU
|
|
Hardness & Scaling Substances
|
Fully removed
|
|
Suspended Solids & Impurities
|
100% intercepted
|
|
Finished Water Status
|
Clear, low conductivity, no scaling risk
|

|
Optional Upgrade
|
Application Function
|
|
Iron & Manganese Removal System
|
Solve groundwater metal ion exceeding problem
|
|
Ultrafiltration Pretreatment
|
Adapt to high-turbidity surface water
|
|
Water Softener
|
Treat high-hardness raw water and prevent scaling
|
|
Double-pass RO / EDI System
|
Produce high-purity industrial water
|
|
UV / Ozone Disinfection
|
Sterilization for domestic and drinking water
|
|
CIP Cleaning System
|
Regular membrane cleaning to extend service life
|
|
PLC Remote Monitoring
|
Real-time water quality data and fault alarm
|
|
Containerized Structure
|
Outdoor mobile installation for remote projects
|
|
Parameter
|
Specification
|
|
Rated Water Output
|
12m³/h
|
|
RO Type
|
Single-pass RO (Double-pass optional)
|
|
Salt Rejection Rate
|
≥97%
|
|
Water Recovery Rate
|
70%–75% (customizable)
|
|
Working Temperature
|
5℃–45℃
|
|
Control Mode
|
Automatic PLC intelligent control
|
|
Pipeline Material
|
UPVC / SS304 / SS316 optional
|
|
Power Supply
|
380V 50/60Hz customizable
|
|
Installation Method
|
Skid-mounted / Containerized
|
Q: Can the equipment run 24 hours continuously?
A: Yes. The industrial-grade fully automatic design supports 24/7 uninterrupted operation, suitable for long-term industrial production scenarios.
Q: Can RO treated water be used for boiler feed water?
A: Yes. It is the ideal pretreatment for boiler water. We can configure double-pass RO or EDI according to different boiler pressure standards.
Q: Is the equipment customizable?
A: Fully customizable. We adjust pretreatment process, material grade, automation level and post-treatment units according to actual water quality and project demands.
Q: Does the system remove iron and manganese from water?
A: RO can reduce part of metal ions. For water with high iron and manganese content, professional removal pretreatment is required.
Q: Can the finished water be used for drinking?
A: It can reach drinking standard with additional UV/ozone disinfection. Final water quality needs to pass local official laboratory testing.