1m³/h Industrial Reverse Osmosis Water Treatment System

The 1m³/h industrial reverse osmosis water treatment system produces up to 1,000 liters of purified water per hour. It combines customized pretreatment with industrial RO membrane technology to reduce dissolved salts, hardness and other contaminants.

Its compact skid-mounted design is suitable for small factories, food and beverage workshops, hotels, laboratories, commercial facilities and community water-supply projects.

The 1m³/h industrial reverse osmosis water treatment system produces up to 1,000 liters of purified water per hour. It combines customized pretreatment with industrial RO membrane technology to reduce dissolved salts, hardness and other contaminants.

Its compact skid-mounted design is suitable for small factories, food and beverage workshops, hotels, laboratories, commercial facilities and community water-supply projects.



Share to
face-book3 Created with Sketch.
linkedln3 Created with Sketch.
Twitter3 Created with Sketch.
Product Description
Industrial Reverse Osmosis Water Treatment

1 m³/h Industrial Reverse Osmosis Water Treatment System

Customized pretreatment and industrial RO membrane technology for up to 1,000 liters of purified water per hour, with a compact skid-mounted design for commercial and industrial applications.

1,000 L/h Rated OutputSingle-Pass Industrial ROAutomatic Operation
1 m³/hRated product-water capacity
97%–99%Typical salt rejection
50%–70%System recovery
24 m³/dayMaximum output at 24 h/day

Actual production depends on feedwater quality, temperature, operating pressure and membrane condition.

Product Overview

Compact Industrial RO Plant

The 1 m³/h industrial reverse osmosis water treatment system combines customized pretreatment with industrial RO membrane technology to reduce dissolved salts, hardness and other contaminants.

Its compact skid-mounted design is suitable for small factories, food and beverage workshops, hotels, laboratories, commercial facilities and community water-supply projects.

Explore more industrial reverse osmosis equipment.

Item Typical Specification
Product name 1 m³/h Industrial Reverse Osmosis Water Treatment System
Product-water capacity 1 m³/h (1,000 L/h)
Maximum daily production Up to 24 m³/day
RO process Single-pass industrial reverse osmosis
Installation Compact skid-mounted system
Control Automatic PLC or relay control
Operating mode Automatic continuous operation
Power supply Customized to local voltage and frequency

Suitable Raw Water

Pretreatment Matched to Water Quality

Municipal Tap Water

Configured according to the local water supply.

Borehole & Well Water

Pretreatment selected according to the raw-water analysis.

Low-Salinity Groundwater

System design considers salinity, hardness and other contaminants.

Rainwater

Suitable pretreatment is required before RO.

River, Lake & Reservoir Water

Surface water must be suitably pretreated.

Process Water

Further purification according to the required water quality.

Standard configuration: feedwater TDS up to approximately 2,000 mg/L.
Higher-salinity groundwater requires suitable BWRO membranes, pumps and pressure vessels.

A raw-water analysis is required when the feedwater contains high hardness, iron, manganese, silica, suspended solids or organic matter.

For high-TDS water, view our brackish water desalination systems.

Product-Water Quality

Designed for Your Application
97%–99%

Typical Salt Rejection

Under suitable design and operating conditions, industrial RO membranes significantly reduce dissolved salts.

Actual product-water TDS depends on feedwater quality, membrane selection and operating conditions.

Lower TDS & Conductivity

Significant reduction in dissolved salts and conductivity.

Reduced Hardness

Substantial reduction in calcium and magnesium hardness.

Dissolved-Ion Reduction

Reduced chloride, sulfate and other dissolved ions.

Industrial Process Water

Clear, low-salinity product water with stable quality for general industrial processes.

For drinking water, food production, laboratory use or boiler feedwater, the complete process must meet the required standard. Additional disinfection, remineralization or polishing treatment may be necessary.

Typical Treatment Process

Customized Pretreatment + RO

Standard Process

Raw WaterRaw-Water TankFeed PumpMultimedia FilterActivated Carbon FilterSoftener or Antiscalant Dosing5 μm Cartridge FilterHigh-Pressure PumpRO Membrane SystemProduct-Water Tank
 
 
 

Borehole Water with High Iron or Manganese

Borehole WaterAeration or OxidationIron and Manganese Removal FilterMultimedia FilterSoftener or Antiscalant DosingCartridge FilterRO SystemProduct-Water Tank
 
 
 

The final pretreatment process is selected according to the raw-water analysis rather than using one fixed configuration for every project. Learn more about our borehole water treatment solutions.

Main Equipment

Typical System Components

Feedwater & Pretreatment

Raw-water feed pump, multimedia filtration system, activated-carbon filter, and water softener or antiscalant dosing unit.

RO Purification

5 μm cartridge security filter, high-pressure pump and industrial RO membrane modules.

Monitoring & Assembly

Pressure gauges, flow meters, online conductivity or TDS meter, automatic control panel, skid-mounted piping and valves.

Tanks, delivery pumps and post-treatment equipment can be included according to the project scope.

Optional Configurations

Build to Project Requirements
Project Requirement Optional Configuration
High-hardness water Automatic water softener
High iron and manganese Oxidation and iron/manganese removal filter
Higher feedwater TDS BWRO membranes and upgraded high-pressure pump
Drinking-water application UV, ozone and remineralization
Higher-purity water Double-pass RO or EDI polishing
Membrane maintenance CIP membrane-cleaning system
Online monitoring TDS, conductivity, pressure and flow instruments
Remote operation PLC, HMI and remote monitoring
Food-grade construction SS304 or SS316L piping and frame
Outdoor installation Containerized enclosure
Local electrical supply Customized voltage, phase and frequency

Technical Parameters

Typical Design Data
Parameter Typical Specification
Product-water capacity 1 m³/h (1,000 L/h)
Maximum daily production Up to 24,000 L/day
Recommended feedwater TDS ≤2,000 mg/L for standard configuration
Typical salt rejection 97%–99%
System recovery 50%–70%
Estimated feedwater demand Approximately 1.43–2.0 m³/h
Feedwater required at 60% recovery Approximately 1.67 m³/h
RO membrane Industrial 4040 membrane
Cartridge filtration 5 μm
Operating temperature Typically 5–40°C
Control system Automatic PLC or relay control
Monitoring Pressure, flow and conductivity/TDS
Frame material SS304 or coated carbon steel
Piping material UPVC, SS304 or SS316L
Power supply 220 V / 380 V, 50 / 60 Hz, customized
Installation Compact skid-mounted structure
Warranty One year

Final parameters must be confirmed through water analysis, membrane calculation and engineering design.

Applications

Commercial & Industrial Water

Food & Beverage

Small food and beverage factories and small bottled-water plants.

Hospitality

Restaurants, hotels and commercial kitchens.

Cosmetics & Personal Care

Water for cosmetic and personal-care production.

Laboratories

Laboratories and testing facilities.

Boiler Feedwater

Pretreatment for boiler feedwater applications.

Equipment Washing

Equipment and container washing.

Schools & Offices

Schools, offices and commercial buildings.

Community Water Supply

Rural communities and construction camps.

Industrial Production

Small industrial production lines.

Applications with specific sanitary, chemical or microbial requirements may require additional treatment and water-quality testing.

Frequently Asked Questions

RO Technical Answers
Does 1 m³/h refer to feedwater or product water?

It refers to the rated RO product-water output. The required feedwater flow is higher and depends on the system recovery rate. At 60% recovery, producing 1 m³/h of purified water requires approximately 1.67 m³/h of feedwater.

Can the system treat borehole water?

Yes. Pretreatment for sediment, hardness, iron and manganese will be selected according to the borehole water analysis.

What feedwater TDS can the system handle?

The standard configuration is generally suitable for feedwater TDS up to approximately 2,000 mg/L. Higher TDS requires a customized brackish-water RO design.

Can the product water be used for drinking?

The system can be configured for drinking-water production. Suitable disinfection and, where required, remineralization must be added. Final water quality should be tested against applicable local standards.

Can the system use 220 V single-phase power?

A 220 V configuration may be available depending on the selected pumps and electrical load. Voltage, phase and frequency must be confirmed before production.

Can the system operate continuously?

Yes. It can support continuous operation when properly sized with adequate raw-water and product-water storage. Routine filter replacement, membrane cleaning and scheduled maintenance are still required.

How much installation space is required?

The dimensions depend on the pretreatment vessels, tanks, pumps and optional equipment. A detailed layout drawing will be provided after the final configuration is confirmed.

Information Required for Quotation

Project Input

Get a Customized 1 m³/h RO Configuration

Provide the following information so our engineers can prepare a suitable system configuration and quotation.

  • Raw-water source
  • Complete water-analysis report
  • Required product-water capacity
  • Intended application
  • Target TDS, conductivity or water-quality standard
  • Daily operating hours
  • Local voltage, phase and frequency
  • Available installation space
  • Project location and destination port
  • Installation and commissioning requirements

Planning a 1 m³/h RO Water Treatment Project?

Send Zhongnuo your water analysis and project information to receive a customized configuration and quotation.

Industrial Reverse Osmosis Water Treatment

1 m³/h Industrial Reverse Osmosis Water Treatment System

Customized pretreatment and industrial RO membrane technology for up to 1,000 liters of purified water per hour, with a compact skid-mounted design for commercial and industrial applications.

1,000 L/h Rated OutputSingle-Pass Industrial ROAutomatic Operation
1 m³/hRated product-water capacity
97%–99%Typical salt rejection
50%–70%System recovery
24 m³/dayMaximum output at 24 h/day

Actual production depends on feedwater quality, temperature, operating pressure and membrane condition.

Product Overview

Compact Industrial RO Plant

The 1 m³/h industrial reverse osmosis water treatment system combines customized pretreatment with industrial RO membrane technology to reduce dissolved salts, hardness and other contaminants.

Its compact skid-mounted design is suitable for small factories, food and beverage workshops, hotels, laboratories, commercial facilities and community water-supply projects.

Explore more industrial reverse osmosis equipment.

Item Typical Specification
Product name 1 m³/h Industrial Reverse Osmosis Water Treatment System
Product-water capacity 1 m³/h (1,000 L/h)
Maximum daily production Up to 24 m³/day
RO process Single-pass industrial reverse osmosis
Installation Compact skid-mounted system
Control Automatic PLC or relay control
Operating mode Automatic continuous operation
Power supply Customized to local voltage and frequency

Suitable Raw Water

Pretreatment Matched to Water Quality

Municipal Tap Water

Configured according to the local water supply.

Borehole & Well Water

Pretreatment selected according to the raw-water analysis.

Low-Salinity Groundwater

System design considers salinity, hardness and other contaminants.

Rainwater

Suitable pretreatment is required before RO.

River, Lake & Reservoir Water

Surface water must be suitably pretreated.

Process Water

Further purification according to the required water quality.

Standard configuration: feedwater TDS up to approximately 2,000 mg/L.
Higher-salinity groundwater requires suitable BWRO membranes, pumps and pressure vessels.

A raw-water analysis is required when the feedwater contains high hardness, iron, manganese, silica, suspended solids or organic matter.

For high-TDS water, view our brackish water desalination systems.

Product-Water Quality

Designed for Your Application
97%–99%

Typical Salt Rejection

Under suitable design and operating conditions, industrial RO membranes significantly reduce dissolved salts.

Actual product-water TDS depends on feedwater quality, membrane selection and operating conditions.

Lower TDS & Conductivity

Significant reduction in dissolved salts and conductivity.

Reduced Hardness

Substantial reduction in calcium and magnesium hardness.

Dissolved-Ion Reduction

Reduced chloride, sulfate and other dissolved ions.

Industrial Process Water

Clear, low-salinity product water with stable quality for general industrial processes.

For drinking water, food production, laboratory use or boiler feedwater, the complete process must meet the required standard. Additional disinfection, remineralization or polishing treatment may be necessary.

Typical Treatment Process

Customized Pretreatment + RO

Standard Process

Raw WaterRaw-Water TankFeed PumpMultimedia FilterActivated Carbon FilterSoftener or Antiscalant Dosing5 μm Cartridge FilterHigh-Pressure PumpRO Membrane SystemProduct-Water Tank
 
 
 

Borehole Water with High Iron or Manganese

Borehole WaterAeration or OxidationIron and Manganese Removal FilterMultimedia FilterSoftener or Antiscalant DosingCartridge FilterRO SystemProduct-Water Tank
 
 
 

The final pretreatment process is selected according to the raw-water analysis rather than using one fixed configuration for every project. Learn more about our borehole water treatment solutions.

Main Equipment

Typical System Components

Feedwater & Pretreatment

Raw-water feed pump, multimedia filtration system, activated-carbon filter, and water softener or antiscalant dosing unit.

RO Purification

5 μm cartridge security filter, high-pressure pump and industrial RO membrane modules.

Monitoring & Assembly

Pressure gauges, flow meters, online conductivity or TDS meter, automatic control panel, skid-mounted piping and valves.

Tanks, delivery pumps and post-treatment equipment can be included according to the project scope.

Optional Configurations

Build to Project Requirements
Project Requirement Optional Configuration
High-hardness water Automatic water softener
High iron and manganese Oxidation and iron/manganese removal filter
Higher feedwater TDS BWRO membranes and upgraded high-pressure pump
Drinking-water application UV, ozone and remineralization
Higher-purity water Double-pass RO or EDI polishing
Membrane maintenance CIP membrane-cleaning system
Online monitoring TDS, conductivity, pressure and flow instruments
Remote operation PLC, HMI and remote monitoring
Food-grade construction SS304 or SS316L piping and frame
Outdoor installation Containerized enclosure
Local electrical supply Customized voltage, phase and frequency

Technical Parameters

Typical Design Data
Parameter Typical Specification
Product-water capacity 1 m³/h (1,000 L/h)
Maximum daily production Up to 24,000 L/day
Recommended feedwater TDS ≤2,000 mg/L for standard configuration
Typical salt rejection 97%–99%
System recovery 50%–70%
Estimated feedwater demand Approximately 1.43–2.0 m³/h
Feedwater required at 60% recovery Approximately 1.67 m³/h
RO membrane Industrial 4040 membrane
Cartridge filtration 5 μm
Operating temperature Typically 5–40°C
Control system Automatic PLC or relay control
Monitoring Pressure, flow and conductivity/TDS
Frame material SS304 or coated carbon steel
Piping material UPVC, SS304 or SS316L
Power supply 220 V / 380 V, 50 / 60 Hz, customized
Installation Compact skid-mounted structure
Warranty One year

Final parameters must be confirmed through water analysis, membrane calculation and engineering design.

Applications

Commercial & Industrial Water

Food & Beverage

Small food and beverage factories and small bottled-water plants.

Hospitality

Restaurants, hotels and commercial kitchens.

Cosmetics & Personal Care

Water for cosmetic and personal-care production.

Laboratories

Laboratories and testing facilities.

Boiler Feedwater

Pretreatment for boiler feedwater applications.

Equipment Washing

Equipment and container washing.

Schools & Offices

Schools, offices and commercial buildings.

Community Water Supply

Rural communities and construction camps.

Industrial Production

Small industrial production lines.

Applications with specific sanitary, chemical or microbial requirements may require additional treatment and water-quality testing.

Frequently Asked Questions

RO Technical Answers
Does 1 m³/h refer to feedwater or product water?

It refers to the rated RO product-water output. The required feedwater flow is higher and depends on the system recovery rate. At 60% recovery, producing 1 m³/h of purified water requires approximately 1.67 m³/h of feedwater.

Can the system treat borehole water?

Yes. Pretreatment for sediment, hardness, iron and manganese will be selected according to the borehole water analysis.

What feedwater TDS can the system handle?

The standard configuration is generally suitable for feedwater TDS up to approximately 2,000 mg/L. Higher TDS requires a customized brackish-water RO design.

Can the product water be used for drinking?

The system can be configured for drinking-water production. Suitable disinfection and, where required, remineralization must be added. Final water quality should be tested against applicable local standards.

Can the system use 220 V single-phase power?

A 220 V configuration may be available depending on the selected pumps and electrical load. Voltage, phase and frequency must be confirmed before production.

Can the system operate continuously?

Yes. It can support continuous operation when properly sized with adequate raw-water and product-water storage. Routine filter replacement, membrane cleaning and scheduled maintenance are still required.

How much installation space is required?

The dimensions depend on the pretreatment vessels, tanks, pumps and optional equipment. A detailed layout drawing will be provided after the final configuration is confirmed.

Information Required for Quotation

Project Input

Get a Customized 1 m³/h RO Configuration

Provide the following information so our engineers can prepare a suitable system configuration and quotation.

  • Raw-water source
  • Complete water-analysis report
  • Required product-water capacity
  • Intended application
  • Target TDS, conductivity or water-quality standard
  • Daily operating hours
  • Local voltage, phase and frequency
  • Available installation space
  • Project location and destination port
  • Installation and commissioning requirements

Planning a 1 m³/h RO Water Treatment Project?

Send Zhongnuo your water analysis and project information to receive a customized configuration and quotation.


Get a Quote for Free
Submit this form and our sales representative will contact you soon.
Name
*Email
Phone
  • Angola+244
  • Afghanistan+93
  • Albania+355
  • Algeria+213
  • Andorra+376
  • Anguilla+1264
  • Antigua and Barbuda+1268
  • Argentina+54
  • Armenia+374
  • Ascension+247
  • Australia+61
  • Austria+43
  • Azerbaijan+994
  • Bahamas+1242
  • Bahrain+973
  • Bangladesh+880
  • Barbados+1246
  • Belarus+375
  • Belgium+32
  • Belize+501
  • Benin+229
  • Bermuda Is.+1441
  • Bolivia+591
  • Botswana+267
  • Brazil+55
  • Brunei+673
  • Bulgaria+359
  • Burkina+faso+226
  • Burma+95
  • Burundi+257
  • Cameroon+237
  • Canada+1
  • Cayman Is.+1345
  • Central African Republic+236
  • Chad+235
  • Chile+56
  • China+86
  • Colombia+57
  • Congo+242
  • Cook Is.+682
  • Costa Rica+506
  • Cuba+53
  • Cyprus+357
  • Czech Republic+420
  • Denmark+45
  • Djibouti+253
  • Dominica Rep.+1890
  • Ecuador+593
  • Egypt+20
  • EI Salvador+503
  • Estonia+372
  • Ethiopia+251
  • Fiji+679
  • Finland+358
  • France+33
  • French Guiana+594
  • Gabon+241
  • Gambia+220
  • Georgia+995
  • Germany+49
  • Ghana+233
  • Gibraltar+350
  • Greece+30
  • Grenada+1809
  • Guam+1671
  • Guatemala+502
  • Guinea+224
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hongkong+852
  • Hungary+36
  • Iceland+354
  • India+91
  • Indonesia+62
  • Iran+98
  • Iraq+964
  • Ireland+353
  • Israel+972
  • Italy+39
  • Ivory Coast+225
  • Jamaica+1876
  • Japan+81
  • Jordan+962
  • Kampuchea (Cambodia )+855
  • Kazakstan+327
  • Kenya+254
  • Korea+82
  • Kuwait+965
  • Kyrgyzstan+331
  • Laos+856
  • Latvia+371
  • Lebanon+961
  • Lesotho+266
  • Liberia+231
  • Libya+218
  • Liechtenstein+423
  • Lithuania+370
  • Luxembourg+352
  • Macao+853
  • Madagascar+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Mariana Is+1670
  • Martinique+596
  • Mauritius+230
  • Mexico+52
  • Moldova, Republic of+373
  • Monaco+377
  • Mongolia+976
  • Montserrat Is+1664
  • Morocco+212
  • Mozambique+258
  • Namibia+264
  • Nauru+674
  • Nepal+977
  • Netheriands Antilles+599
  • Netherlands+31
  • New Zealand+64
  • Nicaragua+505
  • Niger+227
  • Nigeria+234
  • North Korea+850
  • Norway+47
  • Oman+968
  • Pakistan+92
  • Panama+507
  • Papua New Cuinea+675
  • Paraguay+595
  • Peru+51
  • Philippines+63
  • Poland+48
  • French Polynesia+689
  • Portugal+351
  • Puerto Rico+1787
  • Qatar+974
  • Reunion+262
  • Romania+40
  • Russia+7
  • Saint Lueia+1758
  • Saint Vincent+1784
  • Samoa Eastern+684
  • Samoa Western+685
  • San Marino+378
  • Sao Tome and Principe+239
  • Saudi Arabia+966
  • Senegal+221
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Slovakia+421
  • Slovenia+386
  • Solomon Is+677
  • Somali+252
  • South Africa+27
  • Spain+34
  • Sri Lanka+94
  • St.Lucia+1758
  • St.Vincent+1784
  • Sudan+249
  • Suriname+597
  • Swaziland+268
  • Sweden+46
  • Switzerland+41
  • Syria+963
  • Taiwan+886
  • Tajikstan+992
  • Tanzania+255
  • Thailand+66
  • Togo+228
  • Tonga+676
  • Trinidad and Tobago+1809
  • Tunisia+216
  • Turkey+90
  • Turkmenistan+993
  • Uganda+256
  • Ukraine+380
  • United Arab Emirates+971
  • United Kiongdom+44
  • United States of America+1
  • Uruguay+598
  • Uzbekistan+233
  • Venezuela+58
  • Vietnam+84
  • Yemen+967
  • Yugoslavia+381
  • Zimbabwe+263
  • Zaire+243
  • Zambia+260
Company
*Products
Products
  • Reverse Osmosis Equipment
  • EDI Ultrapure Water Equipment
  • Ultrafiltration Equipment
  • Borehole water treatment
  • Brackish Water Desalination Equipment
  • Seawater Desalination Equipment
  • Container Reverse Osmosis Equipment
  • Pretreatment Equipment
*Message