The industrial RO water pretreatment system removes sediment, turbidity, residual chlorine, hardness, organic matter, iron, and manganese before water enters the reverse osmosis unit.
Proper pretreatment reduces RO membrane fouling and scaling, improves system stability, and lowers long-term maintenance costs. Zhongnuo provides customized pretreatment systems from 0.25 m³/h to 100 m³/h for continuous industrial operation.
The industrial RO water pretreatment system removes sediment, turbidity, residual chlorine, hardness, organic matter, iron, and manganese before water enters the reverse osmosis unit.
Proper pretreatment reduces RO membrane fouling and scaling, improves system stability, and lowers long-term maintenance costs. Zhongnuo provides customized pretreatment systems from 0.25 m³/h to 100 m³/h for continuous industrial operation.
The system can be designed for:
The final configuration is selected according to turbidity, hardness, SDI, chlorine, iron, manganese, silica, and organic content.
Raw Water → Raw Water Tank → Feed Pump → Multimedia Filter → Activated Carbon Filter → Water Softener or Antiscalant Dosing → 5 μm Cartridge Filter → RO System
Different water conditions may require additional treatment:
For raw water with heavy suspended solids or microorganisms, an ultrafiltration system can be installed before the industrial RO system.
| Parameter | Typical Design Target |
|---|---|
| Outlet turbidity | ≤1 NTU |
| SDI | ≤3 |
| Cartridge filtration | 5 μm |
| Residual chlorine | Within RO membrane inlet limit |
| Suspended solids | Significantly reduced |
| Scaling risk | Controlled through softening or dosing |
Actual performance depends on the raw-water analysis, treatment process, flow rate, and operating conditions.
| Item | Specification |
| Capacity | 0.25–100 m³/h, customizable |
| Standard process | Multimedia + activated carbon + cartridge filtration |
| Standard inlet turbidity | ≤50 NTU |
| Operating mode | Manual or fully automatic |
| Working temperature | 5–45°C |
| Filter-tank material | FRP, carbon steel, SS304 or SS316 |
| Pipeline material | UPVC or stainless steel |
| Backwashing | Manual or automatic |
| Application | RO and industrial water pretreatment |
| Optional Unit | Main Function |
| Automatic backwashing | Reduces manual operation |
| Water softener | Removes calcium and magnesium hardness |
| Antiscalant dosing | Controls carbonate, sulfate, and silica scaling |
| Iron and manganese filter | Treats colored groundwater and metal deposits |
| Ultrafiltration | Removes fine particles, colloids, and microorganisms |
| Chemical dosing system | Supports oxidation, coagulation, and pH adjustment |
| SS304 or SS316 construction | Suitable for hygienic or corrosive applications |
| PLC control | Automatic operation, monitoring, and alarms |
Industrial RO pretreatment systems are widely used in:
For groundwater applications, refer to our borehole water treatment guide.
Insufficient pretreatment may cause:
The pretreatment process should therefore be based on the actual water report instead of using the same standard configuration for every project.
Yes. The required treatment stages may vary, but sediment control and cartridge filtration are normally necessary to protect RO membranes.
Yes. Iron removal, softening, chemical dosing, ultrafiltration, and other stages can be added according to the raw-water analysis.
Pretreatment flow must satisfy the RO feed-water requirement rather than only the RO product-water capacity. Recovery rate, backwashing demand, and operating margin must also be considered.
Replacement depends on raw-water quality, operating hours, backwashing performance, and media condition. Regular pressure and water-quality monitoring is recommended.
Yes. Automatic backwashing, dosing, water-level control, valve operation, and fault alarms can be integrated through PLC control.
Please provide:
Zhongnuo Water Treatment will select the appropriate filtration process and prepare a customized technical proposal based on your project data.
The system can be designed for:
The final configuration is selected according to turbidity, hardness, SDI, chlorine, iron, manganese, silica, and organic content.
Raw Water → Raw Water Tank → Feed Pump → Multimedia Filter → Activated Carbon Filter → Water Softener or Antiscalant Dosing → 5 μm Cartridge Filter → RO System
Different water conditions may require additional treatment:
For raw water with heavy suspended solids or microorganisms, an ultrafiltration system can be installed before the industrial RO system.
| Parameter | Typical Design Target |
|---|---|
| Outlet turbidity | ≤1 NTU |
| SDI | ≤3 |
| Cartridge filtration | 5 μm |
| Residual chlorine | Within RO membrane inlet limit |
| Suspended solids | Significantly reduced |
| Scaling risk | Controlled through softening or dosing |
Actual performance depends on the raw-water analysis, treatment process, flow rate, and operating conditions.
| Item | Specification |
| Capacity | 0.25–100 m³/h, customizable |
| Standard process | Multimedia + activated carbon + cartridge filtration |
| Standard inlet turbidity | ≤50 NTU |
| Operating mode | Manual or fully automatic |
| Working temperature | 5–45°C |
| Filter-tank material | FRP, carbon steel, SS304 or SS316 |
| Pipeline material | UPVC or stainless steel |
| Backwashing | Manual or automatic |
| Application | RO and industrial water pretreatment |
| Optional Unit | Main Function |
| Automatic backwashing | Reduces manual operation |
| Water softener | Removes calcium and magnesium hardness |
| Antiscalant dosing | Controls carbonate, sulfate, and silica scaling |
| Iron and manganese filter | Treats colored groundwater and metal deposits |
| Ultrafiltration | Removes fine particles, colloids, and microorganisms |
| Chemical dosing system | Supports oxidation, coagulation, and pH adjustment |
| SS304 or SS316 construction | Suitable for hygienic or corrosive applications |
| PLC control | Automatic operation, monitoring, and alarms |
Industrial RO pretreatment systems are widely used in:
For groundwater applications, refer to our borehole water treatment guide.
Insufficient pretreatment may cause:
The pretreatment process should therefore be based on the actual water report instead of using the same standard configuration for every project.
Yes. The required treatment stages may vary, but sediment control and cartridge filtration are normally necessary to protect RO membranes.
Yes. Iron removal, softening, chemical dosing, ultrafiltration, and other stages can be added according to the raw-water analysis.
Pretreatment flow must satisfy the RO feed-water requirement rather than only the RO product-water capacity. Recovery rate, backwashing demand, and operating margin must also be considered.
Replacement depends on raw-water quality, operating hours, backwashing performance, and media condition. Regular pressure and water-quality monitoring is recommended.
Yes. Automatic backwashing, dosing, water-level control, valve operation, and fault alarms can be integrated through PLC control.
Please provide:
Zhongnuo Water Treatment will select the appropriate filtration process and prepare a customized technical proposal based on your project data.