Zhongnuo supplied a 60T/H ultrafiltration pretreatment system for a thermal power plant in Indonesia. The plant used local river water as the source for its double-pass RO boiler-water treatment system.
Seasonal changes caused large fluctuations in river-water turbidity. Suspended sediment, colloids and organic matter frequently entered the pretreatment system, increasing the risk of RO membrane fouling. To stabilize the RO feed-water quality, Zhongnuo designed a large-capacity UF system with automatic backwashing and chemical-cleaning functions.
| Item | Project Details |
|---|---|
| Location | Indonesia |
| Industry | Thermal power generation |
| Application | Boiler-feed-water RO pretreatment |
| Raw water | River water |
| UF capacity | 60m³/h (60000L/H) |
| Membrane type | Industrial hollow-fiber UF membrane |
| Main process | Multimedia filtration + activated carbon + UF |
| Control mode | Automatic PLC operation |




The power plant faced several raw-water and operating problems:
The customer required a reliable 60000L/H UF pretreatment system for a double-pass RO plant that could maintain consistent water quality during continuous operation.
Based on the river-water conditions and downstream RO requirements, Zhongnuo supplied a multi-stage pretreatment system combining conventional filtration with hollow-fiber ultrafiltration.
River Water → Raw Water Tank → Feed Pump → Multimedia Filter → Activated Carbon Filter → Cartridge Filter → Ultrafiltration System → UF Product-Water Tank → Double-Pass RO System → Boiler-Water Treatment

Coagulation and chemical dosing can be added when seasonal turbidity or organic loading exceeds the design range.
| Treatment Unit | Main Function |
|---|---|
| Multimedia filter | Removes sediment and larger suspended particles |
| Activated carbon filter | Reduces organic matter and odor |
| Cartridge filter | Protects UF membranes from coarse particles |
| UF membrane system | Retains fine particles, colloids and many microorganisms |
| Backwash system | Removes accumulated contaminants from the membrane surface |
| CIP system | Restores membrane flux when routine backwashing is insufficient |
| PLC control system | Automates filtration, backwashing, dosing and fault protection |
The 60m³/h industrial ultrafiltration system for power plant boiler water includes:
| Parameter | Project Specification |
|---|---|
| Rated UF output | 60m³/h |
| Feed-water source | River water |
| Filtration precision | Approximately 0.01μm |
| Operating pressure | 0.1–0.3MPa |
| UF recovery rate | More than 90% under design conditions |
| Outlet turbidity | Typically ≤0.1 NTU |
| Outlet SDI | Below 1 under designed operating conditions |
| Control mode | Automatic PLC |
| Downstream process | Double-pass RO |
| Final application | Power-plant boiler-water preparation |
Actual performance depends on seasonal feed-water quality, temperature, membrane flux and cleaning conditions.
After commissioning, the 60T/H UF system for power plant RO pretreatment in Indonesia produced stable feed water for the downstream double-pass RO system.
The project achieved the following results:
The UF system does not remove dissolved salts. Desalination and final boiler-water-quality control are completed by the downstream RO and polishing processes.
River water often changes with rainfall, temperature and seasonal conditions. Conventional filtration alone may not provide consistently low-turbidity and low-SDI water.
A properly designed ultrafiltration system for power plant RO pretreatment can:
UF removes suspended solids, fine particles and colloids that can foul RO membranes. This helps maintain more stable RO pressure and permeate production.
Yes, provided that it is designed for peak seasonal turbidity. Coagulation, sedimentation or enhanced filtration may be required when raw-water quality exceeds the original design range.
No. UF primarily removes particles, colloids and high-molecular-weight contaminants. The downstream RO system removes dissolved salts.
Yes. A modular design allows filtration and backwashing cycles to operate automatically. Standby membrane trains can be added for critical continuous-water applications.
Cleaning frequency depends on feed-water quality and pressure changes. The system uses routine backwashing, chemically enhanced backwashing and periodic CIP cleaning.
Please provide:
Zhongnuo provides customized industrial UF pretreatment systems for power plant boiler water, including process design, factory testing and technical support.
Zhongnuo supplied a 60T/H ultrafiltration pretreatment system for a thermal power plant in Indonesia. The plant used local river water as the source for its double-pass RO boiler-water treatment system.
Seasonal changes caused large fluctuations in river-water turbidity. Suspended sediment, colloids and organic matter frequently entered the pretreatment system, increasing the risk of RO membrane fouling. To stabilize the RO feed-water quality, Zhongnuo designed a large-capacity UF system with automatic backwashing and chemical-cleaning functions.
| Item | Project Details |
|---|---|
| Location | Indonesia |
| Industry | Thermal power generation |
| Application | Boiler-feed-water RO pretreatment |
| Raw water | River water |
| UF capacity | 60m³/h (60000L/H) |
| Membrane type | Industrial hollow-fiber UF membrane |
| Main process | Multimedia filtration + activated carbon + UF |
| Control mode | Automatic PLC operation |




The power plant faced several raw-water and operating problems:
The customer required a reliable 60000L/H UF pretreatment system for a double-pass RO plant that could maintain consistent water quality during continuous operation.
Based on the river-water conditions and downstream RO requirements, Zhongnuo supplied a multi-stage pretreatment system combining conventional filtration with hollow-fiber ultrafiltration.
River Water → Raw Water Tank → Feed Pump → Multimedia Filter → Activated Carbon Filter → Cartridge Filter → Ultrafiltration System → UF Product-Water Tank → Double-Pass RO System → Boiler-Water Treatment

Coagulation and chemical dosing can be added when seasonal turbidity or organic loading exceeds the design range.
| Treatment Unit | Main Function |
|---|---|
| Multimedia filter | Removes sediment and larger suspended particles |
| Activated carbon filter | Reduces organic matter and odor |
| Cartridge filter | Protects UF membranes from coarse particles |
| UF membrane system | Retains fine particles, colloids and many microorganisms |
| Backwash system | Removes accumulated contaminants from the membrane surface |
| CIP system | Restores membrane flux when routine backwashing is insufficient |
| PLC control system | Automates filtration, backwashing, dosing and fault protection |
The 60m³/h industrial ultrafiltration system for power plant boiler water includes:
| Parameter | Project Specification |
|---|---|
| Rated UF output | 60m³/h |
| Feed-water source | River water |
| Filtration precision | Approximately 0.01μm |
| Operating pressure | 0.1–0.3MPa |
| UF recovery rate | More than 90% under design conditions |
| Outlet turbidity | Typically ≤0.1 NTU |
| Outlet SDI | Below 1 under designed operating conditions |
| Control mode | Automatic PLC |
| Downstream process | Double-pass RO |
| Final application | Power-plant boiler-water preparation |
Actual performance depends on seasonal feed-water quality, temperature, membrane flux and cleaning conditions.
After commissioning, the 60T/H UF system for power plant RO pretreatment in Indonesia produced stable feed water for the downstream double-pass RO system.
The project achieved the following results:
The UF system does not remove dissolved salts. Desalination and final boiler-water-quality control are completed by the downstream RO and polishing processes.
River water often changes with rainfall, temperature and seasonal conditions. Conventional filtration alone may not provide consistently low-turbidity and low-SDI water.
A properly designed ultrafiltration system for power plant RO pretreatment can:
UF removes suspended solids, fine particles and colloids that can foul RO membranes. This helps maintain more stable RO pressure and permeate production.
Yes, provided that it is designed for peak seasonal turbidity. Coagulation, sedimentation or enhanced filtration may be required when raw-water quality exceeds the original design range.
No. UF primarily removes particles, colloids and high-molecular-weight contaminants. The downstream RO system removes dissolved salts.
Yes. A modular design allows filtration and backwashing cycles to operate automatically. Standby membrane trains can be added for critical continuous-water applications.
Cleaning frequency depends on feed-water quality and pressure changes. The system uses routine backwashing, chemically enhanced backwashing and periodic CIP cleaning.
Please provide:
Zhongnuo provides customized industrial UF pretreatment systems for power plant boiler water, including process design, factory testing and technical support.